Adopts sensitive CCD Chip
Standard Application
1. Western blot with ECL,ECL Plus
2.DNA/RNA detection(Gel Documentation)
3. Protein gels,Coomassie brilliant blue,SDS Page,Silver staining.
Optional Western Blot applicatioin with RGB fluorescent module.
Model | SH-523 | SH-Advance 523 |
---|---|---|
Digital Camera | Cooled CCD Camera | Cooled CCD Camera |
Physical Resolution | 6 Megapixels,2750*2200 | 6 Megapixels,2750*2200 |
Pixel Density and A/D | 16 Bit | 16 Bit |
Grey Scales | 65536 | 65536 |
Dynamic Range | ≥4.6OD | ≥4.6OD |
Cooling Temperature | -60℃ below ambient, -30℃ regulated | -60℃ below ambient, -30℃ regulated |
Scientifc Lens(Difference between both models) | Sensitive F0.95 Lens | Ultra sensitive F0.8 Lens |
Chemiluminescence sample tray | 4 Layer | 4 Layer |
UV Transmission | 302nm-312nm, area:21x26cm | 302nm-312nm, area:21x26cm |
White LED Transmission | Area: 19x26cm | Area: 19x26cm |
Filter Wheel | FIve position | Five Position |
Filter | Gel Doc Filter | Gel Doc Filter |
UV Protection | UV Protection Shield | UV Protection Shield |
Image Acquisition Software | No software dongle required, unlimited users, free update | No software dongle required, unlimited users, free update |
Image Analysis Software | No software dongle required, unlimited users, free update | No software dongle required, unlimited users, free update |
The optional accessories for this product, please refer to the next label.
Name | Function |
---|---|
Gel doc module with UV transmission | The standard UV with 302nm peak wavelength can be replaced by 365nm or 254nm wavelength. |
Gel Doc with Blue LED plate | Applies gel doc imaging with Blue transmission (incl. 465-485nm Blue LED transmission, Filter wheel with a filter in accordance) |
EPI-UV module | EPI-UV with 365nm UV LED |
Fluorescent module | Fluorescent Western Blot (Refer to the fluorescent dyes) |
FIlter Wheel | Eight Position filter wheel |
WIFI module | Refer to the label of “Optional WIFI module" |
Unlimited OS and smart devices:Supports Windows, Mac OS, Andriod and Harmony OS.
Secure Data storage and transmission:Results can be easily uploaded to claud or shared via email or social media applications.
Ensure the authenticity of the results:The working status of the instrument, the indentity of the personnel and the final results can be uploaded to the server (local or internet) appointed by the users in real time, so that the results must not be modifiable, so as to ensure the authenticity of the results and objective of the data.
Free download, free update, unlimited software users: No software dongles required.